dc.description153p.: (pdf); il; tablas; anexosspa
dc.description.abstractDurante el desarrollo de la práctica empresarial realizada con el objetivo de aplicar los conocimientos de la ingeniería civil, dando apoyo a la realización del proyecto de Reforzamiento estructural, el cual surge del cumplimiento a lo establecido en las Normas Colombianas de Diseño y Construcción Sismo Resistente NRS 98, en cuanto a la revisión de la capacidad sismo resistente de las edificaciones de propiedad del Estado que han sido construidas antes de la vigencia de la NSR 98. Los temas que contiene la práctica empresarial se sustentan en la asistencia en aspectos tantos técnicos como administrativos en el reforzamiento estructural para las centrales de propiedad de Telebucaramanga. Para la época en la que se realizó la proyección de los edificios, no estaba aún vigente el Código de Construcción Sismo Resistente CCCSR-84, ni tampoco se encontraban vigentes las actuales Normas Colombianas de Diseño y Construcción Sismo Resistente NRS 98, Ley 400 de 1997. En esta última norma se establecen parámetros para el diseño y construcción de estructuras nuevas y para la actualización de las existentes construidas antes de la vigencia de la Norma. A si mismo, establece la misma Ley en el articulo 54- Actualización de las edificaciones indispensables, la obligación de realizar estudios de vulnerabilidad sísmica a las edificaciones existentes y ser reforzadas para llevarlas a un nivel de seguridad sísmica equivalente a la de una edificación nueva diseñada y construida de acuerdo con los requerimientos de la misma Ley y sus reglamentos. Del estudio de vulnerabilidad sísmica, se tomó como conclusión que los edificios de las diferentes centrales de Telebucaramanga deben ser intervenidas estructuralmente con el propósito de reducir su vulnerabilidad sísmica, La recomendación por lo tanto, consiste en optar por el reforzamiento y rigidización de la estructura, incrementando las dimensiones de algunas columnas, y adicionando muros de concreto reforzado.spa
dc.description.abstractDuring the development of the empresarial practice made with the objective of applying the knowledge of the civil engineering, giving support to the creation of the project of structure reinforcement, the one who starts from the accomplishment of the established in the Colombian rules of design and construction resistant sism NRS 98 ,as far to the revision of the capacity sism resistance of the buildings of the state property that have been built before of the vigency of the NSR 98. The topics that the empresarial practice contain are presented in assistance of technical and administrative aspects in the structural reinforcements for the central proprieties of Telebucaramanga.For the time that the projection of the buildings was made, it wasn’t able the code of construction sism resistant CCCSR-84, not either the actual Colombian rules of design and construction sism resistant NRS 98, law 400 of 1997. In this last rule are established parameters for the design and construction of new structures and for the actualization of the already built before of the vigency of the law. So as itself the same law establishes in the article 54 the actualizations of the necessary buildings, the obligation of making studies of sismic vulnerability to the existent edifications and to be reinforced to take them to a new level of sismic security that equals to a new designed and built edification with the requirements of the same law and its rules.The study of sismic vulnerability, was taken as a conclusion that the buildings of the various central structurally Telebucaramanga be tapped in order to reduce sismic vulnerability, The recommendation therefore is to opt for the strengthening and stiffening of the structure, increasing the size of some columns, and adding reinforced concrete walls.
dc.language.isoes
dc.publisherUniversidad Pontificia Bolivarianaspa
dc.rightsAttribution-NonCommercial-NoDerivatives 4.0 International*
dc.rights.urihttp://creativecommons.org/licenses/by-nc-nd/4.0/*
dc.subjectTesis y disertaciones académicasspa
dc.subjectIngeniería civilspa
dc.subjectNorma colombiana de diseño y construcción sismo resistentes NRS 98spa
dc.subjectLey 400 DE 1997spa
dc.titleAuxiliar de interventoría para la ejecución de las recomendaciones arrojadas por el estudio de vulnerabilidad sísmica para las centrales de Telebucaramangaspa
dc.typeworkingPaperspa
dc.rights.accessRightsopenAccessspa
dc.type.hasVersionpublishedVersionspa
dc.identifier.instnameinstname:Universidad Pontificia Bolivarianaspa
dc.identifier.reponamereponame:Repositorio Institucional de la Universidad Pontificia Bolivarianaspa
dc.identifier.repourlrepourl:https://repository.unab.edu.co/


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record

Attribution-NonCommercial-NoDerivatives 4.0 International
Except where otherwise noted, this item's license is described as Attribution-NonCommercial-NoDerivatives 4.0 International