Show simple item record

dc.contributor.advisorDirector. Cuervo Andrade, Sandra Patricia
dc.contributor.authorCardenas Herrera, Santiago
dc.contributor.authorParra Almanza, Lina María
dc.coverage.temporal2019
dc.date.accessioned2021-01-19T17:00:31Z
dc.date.available2021-01-19T17:00:31Z
dc.date.issued2019-07
dc.identifier.urihttp://hdl.handle.net/20.500.11912/7432
dc.description114p.: (pdf); il; imágenes; tablas; gráficas; anexos.spa
dc.description.abstractLa tecnología del secado ha crecido considerablemente, sin embargo, debido al costo del proceso, pocos tienen acceso a esta tecnología ya que demanda un alto consumo energético. Como alternativa ante esta problemática se encuentra el secado solar, que aprovecha la radiación del sol para la obtención de energía eléctrica y energía térmica. Lo túneles de secado funcionan basados en este principio y aunque muchas veces es complejo controlar la temperatura y la humedad dentro de la cámara de secado, sí se puede llegar a saber de qué manera el túnel funciona mejor combinando diferentes parámetros de construcción. El siguiente trabajo de grado es un estudio realizado del comportamiento que presenta la temperatura y la humedad dentro de un túnel de secado solar tipo Hohenheim. De acuerdo las combinaciones obtenidas del diseño factorial fraccionado se hizo la respectiva toma de datos. Del análisis de los resultados se observó que las condiciones climáticas, la aparición de nubes y el viento afectan notablemente los resultados obtenidos. A demás de esto, las variables estudiadas, cambiaban de una prueba a otra dependiendo de la combinación correspondiente.spa
dc.description.abstractDrying technology has grown considerably, but the energy cost of the process is too high just a few people can use it. One of the alternatives for this problem is the solar drying, this use sun’s radiation to obtain electrical energy and thermal energy. The drying tunnel work based on this principle and is hard control the temperature and humidity in the drying chamber, but we can predict how work better mixing differents parameters. The next undergraduate work it is a study of temperature and humidity behavior inside a Hohenheim type solar drying tunnel. According to the combinations in the fractional factorial design and the data collection was made using it. In the analysis of result was obtained that the weather, the clouds and the wind affect the results obtained. The variables studied change from one proof to another proof.eng
dc.format.mimetypeapplication/pdf
dc.language.isospa
dc.publisherUniversidad Pontificia Bolivarianaspa
dc.rightsAttribution-NonCommercial-NoDerivatives 4.0 International*
dc.rights.urihttp://creativecommons.org/licenses/by-nc-nd/4.0/*
dc.subjectSecado solarspa
dc.subjectHohenheimspa
dc.subjectTúnelesspa
dc.subjectSistemas de recolección automática de datosspa
dc.subjectDeshidratadorspa
dc.titleCaracterización del túnel de secado solar tipo Hohenheimspa
dc.typeTrabajo de gradospa
dc.publisher.departmentEscuela de Ingenieríasspa
dc.publisher.programIngeniería Mecánicaspa
dc.type.hasVersionpublishedVersionspa
dc.description.sectionalBucaramangaspa
dc.description.degreenameIngeniero Mecánicospa


Files in this item

Thumbnail
Thumbnail

This item appears in the following Collection(s)

Show simple item record

Attribution-NonCommercial-NoDerivatives 4.0 International
Except where otherwise noted, this item's license is described as Attribution-NonCommercial-NoDerivatives 4.0 International