Implementación del primer anillo de calibración del Banco de Medición de Flujo de agua basado en la Norma Técnica Colombiana NTC 1063 para el Laboratorio de Instrumentac
dc.contributor.advisor | Mantilla Saavedra, Juan Carlos | |
dc.contributor.author | Gómez Álvarez, Alvaro Daniel | |
dc.coverage.temporal | 2013 | |
dc.date.accessioned | 2020-09-15T16:10:12Z | |
dc.date.available | 2020-09-15T16:10:12Z | |
dc.date.issued | 2013 | |
dc.identifier.uri | http://hdl.handle.net/20.500.11912/6020 | |
dc.description | 94 páginas | spa |
dc.description.abstract | Se desarrolló un rediseño del banco de ensayos y calibración de medidores de flujo de agua de manera tal que cumpliera con los requisitos de la Norma Técnica Colombiana NTC 1063 y que a su vez se adaptará a las condiciones del laboratorio de instrumentación de la Universidad Pontificia Bolivariana; para este rediseño se tuvo en cuenta lo estipulado en la fase 1 y fase 2 del proyecto. Lo primero fue desarrollar un diseño de los tanques patrones, en los cuales se deseó tener una capacidad de almacenamiento máxima de 240 litros lo cual permite realizar pruebas de calibración con caudales superiores a 100 l/min, la ubicación de los tanques patrones se tomó de la distribución de espacio hecha en la fase 2. Para el diseño de los tanques patrones y la distribución de la tubería se usó el software Solidwork; basando todo en los diseños de la fase 1 y 2 así como en la Norma Técnica Colombiana NTC 1063. La fase 3 se centró en la implementación del primer anillo de calibración el cual usa el método de calibración por volumen conocido que se encuentra contemplado en la norma, el objetivo del anillo de calibración es realizar pruebas las cuales permitan parametrizar y revisar la calibración de los dispositivos de medición de flujo de agua. La proyección del banco de ensayos y calibración abarca la implementación del sistema de pérdidas por diferentes diámetros, codos y la implementación de RTDs que permitan medir la temperatura del agua a la entrada y la salida. Finalmente se elaboró el dossier del proyecto y la guía del laboratorio. | spa |
dc.description.abstract | We developed a test bench redesign and calibration of water flow meters in a manner that meets the requirements of the Colombian Technical Standard NTC 1063 and that in turn is adapted to the conditions of the instrumentation laboratory at the Universidad Pontificia Bolivariana, for this redesign was taken into account as provided in Phase 1 and Phase 2 of the project. The first was to develop a tank design pattern in which it was desired to have a maximum storage capacity of 240 liters, which allows testing of calibration flows exceeding 100 I / min, the location of the tanks is made of patterns space allocation made in phase 2. For the design of the tanks and the distribution patterns of the pipe was used Solidwork software, basing everything on the designs of phase 1 and 2 and in the Colombian Technical Standard NTC 1063. Phase 3 focused on the implementation of the first ring calibration which uses the calibration method known volume which is covered by the standard, the calibration target is ring which allow testing and review calibration measuring devices water flow. The bank's forecast covers testing and calibration system implementation losses of different diameters, elbows and implementation of RTDs to measure the water temperature at the inlet and outlet. Finally, the project developed the dossier and laboratory guide. | eng |
dc.format.mimetype | application/pdf | |
dc.language.iso | spa | |
dc.publisher | Universidad Pontificia Bolivariana | spa |
dc.rights | Attribution-NonCommercial-NoDerivatives 4.0 International | * |
dc.rights.uri | http://creativecommons.org/licenses/by-nc-nd/4.0/ | * |
dc.subject | Normas técnicas - NTC1063 | spa |
dc.subject | Instrumentación | spa |
dc.subject | Universidades - Universidad Pontificia Bolivariana | spa |
dc.subject | Laboratorios | spa |
dc.subject | Válvulas | spa |
dc.subject | Software - Solidworks | spa |
dc.title | Implementación del primer anillo de calibración del Banco de Medición de Flujo de agua basado en la Norma Técnica Colombiana NTC 1063 para el Laboratorio de Instrumentac | spa |
dc.type | Trabajo de grado | spa |
dc.publisher.department | Escuela de Ingenierías | spa |
dc.publisher.program | Ingeniería Electrónica | spa |
dc.type.hasVersion | publishedVersion | spa |
dc.description.sectional | Bucaramanga | spa |
dc.description.degreename | Ingeniero Electrónico | spa |