dc.contributor.advisor | Hernández Arroyo, Emil | |
dc.contributor.author | Cely Valderrama, Elkin Jonathan | |
dc.contributor.author | Pérez Carreño, Jhon Mario | |
dc.coverage.temporal | 2018 | |
dc.date.accessioned | 2020-05-19T17:46:07Z | |
dc.date.available | 2020-05-19T17:46:07Z | |
dc.date.issued | 2018 | |
dc.identifier.uri | http://hdl.handle.net/20.500.11912/5423 | |
dc.description | 49p.: (pdf); il; imágenes; gráficas; tablas; anexos. | spa |
dc.description.abstract | En este proyecto, se diseña, construye y evalúa el desempeño de un banco hidráulico que emplea una bomba centrífuga operando como turbina. El uso de bombas centrífugas funcionando como turbinas ya ofrece una alternativa técnica económicamente viable y, por tanto, contribuye a la aplicación en pequeñas centrales hidráulicas. Un sistema cerrado existente que provee un potencial hidráulico se usó para adaptar la bomba centrífuga, se requirió de un diseño preliminar para calcular la capacidad de la bomba seleccionada, además, de las correspondientes adaptaciones mecánicas para su correcto funcionamiento. Ya ensamblado el sistema fue posible verificar su funcionamiento, medir variables de interés y evaluar su desempeño. El equipo construido cumple con el propósito planteado, gracias a la potencia hidráulica entregada en el punto de mayor eficiencia a la bomba operando como turbina, se sostuvo una carga de 70Watts a 120 Voltios y cabe destacar que con un presupuesto económico menos limitado se pueden adquirir componentes que permitan obtener mejores resultados. | spa |
dc.description.abstract | In this project, the performance of a hydraulic bench that uses a centrifugal pump operating as a turbine is designed, constructed and evaluated. The use of centrifugal pumps operating as turbines already offers an economically viable technical alternative and, therefore, contributes to the application in small hydraulic power plants. An existing closed system that provides a hydraulic potential was used to adapt the centrifugal pump, a preliminary design was required to calculate the capacity of the selected pump, besides, of the corresponding mechanical adaptations for its correct operation. Once the system was assembled, it was possible to verify its operation, measure variables of interest and evaluate its performance. The built equipment fulfills the stated purpose, thanks to the hydraulic power delivered at the best efficiency point to the pump operating as a turbine, a load of 70Watts was sustained at 120 Volts and it should be noted that with a less limited economic budget can be acquired components that allow obtaining better results. | eng |
dc.format.mimetype | application/pdf | |
dc.language.iso | spa | |
dc.publisher | Universidad Pontificia Bolivariana | spa |
dc.rights | Attribution-NonCommercial-NoDerivatives 4.0 International | * |
dc.rights.uri | http://creativecommons.org/licenses/by-nc-nd/4.0/ | * |
dc.subject | Bombas centrífugas | spa |
dc.subject | Turbinas | spa |
dc.subject | Eficiencia mecánica | spa |
dc.subject | Hidráulica | spa |
dc.title | Evaluación del desempeño de una bomba centrífuga operando como turbina | spa |
dc.type | Práctica | spa |
dc.publisher.department | Escuela de Ingenierías | spa |
dc.publisher.program | Ingeniería Mecánica | spa |
dc.type.hasVersion | publishedVersion | spa |
dc.description.sectional | Bucaramanga | spa |
dc.description.degreename | Ingeniero Mecánico | spa |