dc.contributor.advisor | Guzmán Serna, Fabio Alonso | |
dc.contributor.author | Ruiz Ardila, Sandra Milena | |
dc.contributor.author | Guarin Rueda, Juan Carlos | |
dc.coverage.spatial | Seccional Bucaramanga. Universidad Pontificia Bolivariana. Escuela de Ingenierías. Facultad de Ingeniería Electrónica | spa |
dc.coverage.temporal | 2009 | |
dc.date.accessioned | 2013-07-16T21:53:50Z | |
dc.date.available | 2013-07-16T21:53:50Z | |
dc.date.created | 2009-10-16 | |
dc.date.issued | 2013-07-16 | |
dc.identifier.uri | http://hdl.handle.net/20.500.11912/539 | |
dc.description | 81p.: (pdf); il; gráficas; tablas; anexos | spa |
dc.description.abstract | La idea principal para el desarrollo de éste proyecto surge como consecuencia de las necesidades frecuentes en la implmentación de dispositivos con características tecnológicas, que permitan desempeñar aplicaciones de mayor complejidad y procesamiento. Este proyecto implementa una tarjeta de adquisicón capaz de obtener las señales electromiográficas provenientes del miembro superior de una persona, para luego procesar la información y visualizarla en una PC. El hardware del sistema está construido en base a una placa de adquisición y un circuito analógico de entrada, que permite capturar las pequeñas señales provenientes del músculo. Considerando el ancho de banda que ocupan estas señales y la baja amplitud de ellas, se tuvo que ser muy riguroso con el filtrado, primero para atenuar la señal de entrada dentro de su rango característico,segundo para discernir a esta señal del ruido proveniente del ambiente y de la línea, que como se verá a lo largo del trabajo son las fuentes de mayor interferencia en las señales electromiográficas, para posteriormente amplificarla. Adicionalmente, se implementó un circuito de muestreo y retención de ampliktud el cual mantiene un nivel DC diferente de cero, mientrasexista en la entrada de este circulo una señal electromiográfica proveniente de algún músculo esquelético. El software fue desarrollado utilizando un lenguaje de programación a nivel objeto (labview 8.2) para la adquisición y almacenamiento de la señal electromiográfica, de manera de lograr una interfaz gráfica agradable y de fácil manejo para el usuario. A lo largo del documentoi se explicará paso a paso cada una de las etapas en detalle implementadas y se brindará suficiente información para que elusuario que desee leerlo pueda localizar lo que busca y comprenderlo rápidamente. | spa |
dc.description.abstract | The development of this project arises as a consequence of the frequent needs in the implementation of devices with technological characteristics, that allow for applications with more complexity and processing. This project implements an acquisition card capable of electromyographic signals from the upper limb of a person, and then process the information and display it on a PC. The hardware system is built on an acquisition board and a circuit analog input, which can capture small signals from the muscle. Considering the bandwidth occupied by these signals and the low amplitude of them had to be very strict with filtering, first to reduce the input signal within its typical range, second to discern a signal from the ambient noise and the line, as will be seen throughout the work are the biggest sources of interference in the electromyographic signal, then amplified. Additionally, a circuit implemented sampling and retention amplitude level which maintains a DC different from zero, while the entry exists in this circuit an electromyographic signal from a skeletal muscle. The software was developed using a programming language-level object (LabVIEW 8.2) for the purchase and storage of the electromyographic signal, so as to achieve a nice graphical interface and easy to handle for the user. Throughout the document will explain step by step, each step in detail and implemented will provide enough information for the user you want to read it can find and understand what you are looking for quickly. | spa |
dc.language.iso | es | |
dc.publisher | Universidad Pontificia Bolivariana | spa |
dc.rights | Attribution-NonCommercial-NoDerivatives 4.0 International | * |
dc.rights.uri | http://creativecommons.org/licenses/by-nc-nd/4.0/ | * |
dc.subject | Tesis y disertaciones académicas | spa |
dc.subject | Ingeniería electrónica | spa |
dc.subject | Labview [Programas para computador] | spa |
dc.subject | Amplificadores [Electrónica] | spa |
dc.subject | Electromiografía | spa |
dc.title | Actualización tecnológica del módulo de tratamiento de señales electromiográficas | spa |
dc.type | bacherlorThesis | spa |
dc.rights.accessRights | openAccess | spa |
dc.type.hasVersion | publishedVersion | spa |
dc.identifier.instname | instname:Universidad Pontificia Bolivariana | spa |
dc.identifier.reponame | reponame:Repositorio Institucional de la Universidad Pontificia Bolivariana | spa |
dc.identifier.repourl | repourl:https://repository.unab.edu.co/ | |