dc.contributor.advisor | Castillo Pérez, Consuelo | |
dc.contributor.author | Cárdenas Escobar, David | |
dc.coverage.spatial | Seccional Bucaramanga. Universidad Pontificia Bolivariana. Escuela de Ingenierías. Facultad de Ingeniería Ambiental | spa |
dc.coverage.temporal | 2009 | |
dc.date.accessioned | 2013-07-16T21:53:46Z | |
dc.date.available | 2013-07-16T21:53:46Z | |
dc.date.created | 2009-07-24 | |
dc.date.issued | 2013-07-16 | |
dc.identifier.uri | http://hdl.handle.net/20.500.11912/511 | |
dc.description | 83p.: (pdf); il; tablas; gráficas | spa |
dc.description.abstract | El trabajo implementa un sistema de monitoreo para realizar una evaluación de calidad de aire en una zona aledaña al ICP. Se decidió evaluar y monitorear los compuestos orgánicos volátiles ya que en una empresa petrolera los VOC´s son los compuestos de mayor presencia en las emisiones del procedimiento de la combustión, y en otro cualquier tratamiento o manejo que se le haga acabo a los hidrocarburos. Con base a la normatividad Colombiana, Resolución 0601 de 2006, por la cual se establece la norma de calidad de aire, se realizo un estudio para establecer que compuestos deberán ser identificados y monitoreados en la zona adjunta del ICP. Se optó por monitorear 23 compuestos en los cuales fueron evaluados en horas de la mañana, de la tarde y de la noche en 6 días de la semana (lunes a sábado) durante 2 meses con un equipo portátil medidor de VOC´s. También se realizó un diagnóstico meteorológico para evaluar la estabilidad atmosférica de la zona. Dentro la urbanización se tomó 4 puntos en donde se hizo muestreo de los 23 compuestos. Se concluyó que gran proporción del viento va a dirección al sur-oeste colocando la urbanización Pinares Campestre como mayor receptor de corriente de vientos procedente del ICP. Al comparar los resultados obtenidos del monitoreo puntal de los compuestos orgánicos volátiles con la normatividad Colombiana no se presentó ningún dato fuera del límite máximo establecido por la Resolución 0601 de 2006, esto quiere decir que ECOPETROL S.A. cumple con esta norma y que no está violando ninguna ley establecida por el gobierno Colombiano según este estudio preliminar ya que lo que se realizó fue un muestreo puntal. | spa |
dc.description.abstract | This work implements a monitoring system of air quality in an area near to the ICP. It was decided to evaluate the volatile organic compounds as that an oil company the VOC´s are present in higher emissions from the combustion process, and any other treatment or management that have done to the hydrocarbons. Based on the Colombian legislation, Resolution 0601 of 2006, which sets the standard for air quality, we conducted a study to establish which compounds should be identified and monitored in the area next to the ICP. We decided to take samples of 23 compounds which were evaluated in the morning, the afternoon and evening, 6 days a week (Monday to Saturday) for 2 months with a portable meter VOC's. Was also performed a diagnostic meteorological atmospheric stability of the area. Inside the urbanization was taken 4 points where the sampling was done for the 23 compounds. It was concluded that a large proportion of the wind direction is going to the south-west placing urbanization Pinares Campestre as largest recipient of wind flow from the ICP. By comparing the results obtained from the evaluation of volatile organic compounds with the Colombian law did not provide information beyond the data established by Resolution 0601 of 2006, this means that ECOPETROL S.A. satisfies this standard and is not violating any law established by the Colombian government as this was preliminary study. | spa |
dc.language.iso | es | |
dc.publisher | Universidad Pontificia Bolivariana | spa |
dc.rights | Attribution-NonCommercial-NoDerivatives 4.0 International | * |
dc.rights.uri | http://creativecommons.org/licenses/by-nc-nd/4.0/ | * |
dc.subject | Ingeniería ambiental | spa |
dc.subject | Tesis y disertaciones académicas | spa |
dc.subject | Contaminación atmosférica | spa |
dc.subject | Calidad del aire | spa |
dc.title | Evaluación de calidad de aire, compuestos orgánicos volátiles -VOC´s, en zona aledaña del Instituto Colombiano del Petróleo (ICP) - ECOPETROL S.A | spa |
dc.type | bacherlorThesis | spa |
dc.rights.accessRights | openAccess | spa |
dc.type.hasVersion | publishedVersion | spa |
dc.identifier.instname | instname:Universidad Pontificia Bolivariana | spa |
dc.identifier.reponame | reponame:Repositorio Institucional de la Universidad Pontificia Bolivariana | spa |
dc.identifier.repourl | repourl:https://repository.unab.edu.co/ | |