dc.description.abstract | Las válvulas de control, es el sistema utilizado para regular el flujo, dentro de un proceso especifico. Con este fin; se diseñó, construyó e implementó un prototipo de una válvula de control en lazo abierto, que se adaptara a las especificaciones de trabajo del sistema de enfriamiento de la planta térmica, ubicado en el laboratorio de plantas térmicas de la UPB. Para uso exclusivo del área académica. El sistema de la válvula es completamente diferente a los que existe en el mercado, ya que es controlada por un LOGO 12/24 RC (PLC); el cual compara la señal externa (Posición de apertura determinada por el Operador), con la interna. Las señales provienen de la variación de dos potenciómetros lineales. La exactitud en la posición del vástago de la válvula, es dada por la relación de velocidad del sistema de transmisión de potencia. Con las pruebas realizadas al prototipo, se grafico la curva de pérdidas de presión vs caudal; concluyéndose la eficiencia del mismo. | spa |
dc.description.abstract | Valve control is the system used to regulate the flow within a specific process. To this
end, it was designed, built and implemented a prototype of a control valve in open loop,
which is geared to the specific work of the cooling system of the thermal plant, located
in the laboratory of the Unit of thermal plants. For exclusive use by the academic area.
The valve system is completely different from those in the market because it is
controlled by a LOGO 12/24 RC (PLC), which compares the external signal (open
position given by the Operator) with the internal . The signals come from the variation of
two linear potentiometers. The accuracy in the position of the valve rod is given by the
ratio of velocity power transmission system. In testing the prototype, is the curve graph
of pressure vs. flow losses, the efficiency of the same conclusion. | |
dc.language.iso | es | |
dc.rights | Attribution-NonCommercial-NoDerivatives 4.0 International | * |
dc.rights.uri | http://creativecommons.org/licenses/by-nc-nd/4.0/ | * |
dc.subject | Ingeniería mecánica | spa |
dc.subject | Tesis y disertaciones académicas | spa |
dc.subject | Ingeniería mecánica | spa |
dc.subject | Refrigeración | spa |
dc.subject | Almacenamiento en frío | spa |
dc.subject | Valvula - control PLC | spa |
dc.subject | Universidad Pontificia Bolivariana - Regrigeración - Laboratorio de plantas | spa |
dc.title | Diseño, construcción e implementación de una valvula de control por PLC en lazo abierto, para el sistema de refrigueración del laboratorio de plantas de la Universidad Pontificia Bolivariana | spa |
dc.type | bacherlorThesis | spa |
dc.rights.accessRights | openAccess | spa |
dc.type.hasVersion | publishedVersion | spa |
dc.identifier.instname | instname:Universidad Pontificia Bolivariana | spa |
dc.identifier.reponame | reponame:Repositorio Institucional de la Universidad Pontificia Bolivariana | spa |
dc.identifier.repourl | repourl:https://repository.unab.edu.co/ | |