Mostrar el registro sencillo del ítem

dc.contributor.advisorMagara Gómez, Kento Taro
dc.contributor.authorOspina López, Juan Diego
dc.coverage.spatialSeccional Bucaramanga. Universidad Pontificia Bolivariana. Escuela de Ingenierías. Facultad de Ingeniería Ambientalspa
dc.coverage.temporal2008
dc.date.accessioned2013-06-21T19:23:21Z
dc.date.available2013-06-21T19:23:21Z
dc.date.issued2013-06-21
dc.identifier.urihttp://hdl.handle.net/20.500.11912/209
dc.description189p.: (pdf); il; tablas; gráficas; anexosspa
dc.description.abstractDesde hace un tiempo atrás, la población del Barrio Claverianos, ubicada en la Salida Norte de Bucaramanga, viene presentando sus quejas ante las entidades departamentales por los inconvenientes causados por la contaminación debido al material particulado. La empresa CEMEX S.A., ubicada a 600 metros de este barrio y preocupado por la salud de sus habitantes, ha buscado desarrollar estrategias junto con la CDMB para determinar la dispersión de sus contaminantes y así definir su aporte contaminante al barrio, para tal fin se decidió aplicar el Software de modelación de la calidad de aire BREEZE para modelar la dispersión de Material Particulado, PM-10, ya que esta es la principal emisión de la planta cementera; para esta modelación fue necesaria la colaboración conjunta de Universidad - Empresa Privada - Estado, representados estos en la Universidad Pontificia Bolivariana, CEMEX S.A. y Corporación de Defensa de la Meseta de Bucaramanga (CDMB). La CDMB junto con CEMEX S.A. aportaron todos los datos a su alcance, como fueron la data meteorológica y datos de muestreos isocinéticos y de calidad de aire. Con estos datos se procedió a trabajar con el software y posteriormente analizar los resultados. Los resultados arrojados por la modelación mostraron una tendencia de los contaminantes a dirigirse al sur, lugar dónde se encuentra el Barrio Claverianos, pero siempre mostrando unos valores por debajo del límite máximo permitido de 150 μg/m3 exigido por la Resolución 601 de 4 de Abril de 2006. También se encontró que fueron las carreteras al interior de la cementera las que más material particulado aportaron a la modelación, por encima de las fuentes puntuales del proceso de triturado, molienda, mezcla y empaque. Igualmente se concluyó la modelación con porcentajes de error del orden del 35% lo cual es un valor aceptable para trabajos de modelación de dispersión de contaminantes.spa
dc.description.abstractSince long time ago, the population of Claverianos neighborhood, located in the north side exit of Bucaramanga, has been presenting several complaints to the departmental entities for the inconveniences caused by the particular matter pollution. The Factory CEMEX S.A., located 600 meters from Claverianos neighborhood, has been worried about the health of the habitants of this neighborhood; CEMEX S.A. has been developing strategies with the CDMB in order to determine the dispersion of their pollutants and in that way define their pollution contribution to Claverianos neighborhood, for this purpose it was decided to implement the air quality modeling software BREEZE to model the dispersion of particular matter, PM-10, because this is the principal emission of this cement plant; for this modeling implementation it was necessary the collaboration of the University – Private company – State, represented by Universidad Pontificia Bolivariana, CEMEX S.A. and Corporación de Defensa de la Meseta de Bucaramanga (CDMB). The CDMB and CEMEX S.A. contributed with all the data that they had, this is the meteorological data, the isokinetics sampling data and the air quality data. After having all this data collected, it was able to proceed to work with the software and after running the software the results were analyzed. The modeling results show a tendency of the pollutants to move to the south, which is the place where Claverianos neighborhood is located, but the results were showing low values under de maximum permit limit of 150 µg/m3 required by the Resolution 601 of April 4 of 2006. Also it was found that the roads inside this cement plant contributed with more particular matter than the point sources from the processes of Crushing, Milling, Blending and Packing. In the same order the modelation were finished with a error of 35% which is acceptable for this kind of Air Dispersion Models.spa
dc.language.isoes
dc.publisherUniversidad Pontificia Bolivarianaspa
dc.rightsAttribution-NonCommercial-NoDerivatives 4.0 International*
dc.rights.urihttp://creativecommons.org/licenses/by-nc-nd/4.0/*
dc.subjectIngeniería ambientalspa
dc.subjectTesis y disertaciones académicasspa
dc.subjectCalidad del airespa
dc.subjectContaminación del aire - control industrialspa
dc.subjectSoftware Breeze modelación de calidad del aire [Programa para computador]spa
dc.titleImplementación del software Breeze de modelación de la calidad de aire para material particulado, PM-10, en la planta productora de cemento Cemex S.A., ubicada en la salidad norte de Bucaramangaspa
dc.typebacherlorThesisspa
dc.rights.accessRightsopenAccessspa
dc.type.hasVersionpublishedVersionspa
dc.identifier.instnameinstname:Universidad Pontificia Bolivarianaspa
dc.identifier.reponamereponame:Repositorio Institucional de la Universidad Pontificia Bolivarianaspa
dc.identifier.repourlrepourl:https://repository.unab.edu.co/


Ficheros en el ítem

Thumbnail

Este ítem aparece en la(s) siguiente(s) colección(ones)

Mostrar el registro sencillo del ítem

Attribution-NonCommercial-NoDerivatives 4.0 International
Excepto si se señala otra cosa, la licencia del ítem se describe como Attribution-NonCommercial-NoDerivatives 4.0 International