Reorganización del módulo de temperatura con la implementación del proceso de configuración de transmisores en el laboratorio de instrumentación de la UPB
dc.contributor.advisor | Mantilla Saavedra, Juan Carlos | |
dc.contributor.author | Vargas Cetina, Mayra Alejandra | |
dc.contributor.author | Estupiñán Blanco, Carlos Andres | |
dc.coverage.spatial | Bucaramanga | spa |
dc.coverage.temporal | 2021 | spa |
dc.date.accessioned | 2025-05-02T19:39:46Z | |
dc.date.available | 2025-05-02T19:39:46Z | |
dc.date.issued | 2021 | |
dc.identifier.uri | http://hdl.handle.net/20.500.11912/12539 | |
dc.description | 117 Páginas | spa |
dc.description.abstract | En este proyecto se presenta la reorganización del módulo de temperatura del laboratorio de instrumentación de la UPB seccional Bucaramanga implementando el proceso de configuración de transmisores. Inicialmente se presenta el reconocimiento y el análisis de las condiciones actuales del módulo de temperatura, así como de las condiciones de operación de éste. Lo anterior es llevado a cabo mediante un inventario de cada uno de los instrumentos que integran el módulo de temperatura. Seguidamente, se realiza el diseño de la estructura del tablero de instrumentos y la distribución de los elementos teniendo en cuenta el espacio disponible en el laboratorio, las especificaciones de los instrumentos y el análisis realizado previamente. Posteriormente, para la implementación de los transmisores de temperatura, inicialmente se realizó la configuración requerida para poner en funcionamiento los transmisores. El método utilizado para la implementación fue un lazo de corriente de 4-20 mA a través de un circuito en serie. Para comprobar el funcionamiento del lazo de corriente se realizaron pruebas a los transmisores en donde se registraron los valores de temperatura contra resistencia y corriente. Luego, los resultados obtenidos de las pruebas de operación fueron analizados indicando que la relación existente entre temperatura y corriente es una respuesta completamente lineal una vez el transmisor de temperatura incorpora la señal de la RTD y convierte esta al estándar 4-20 mA. Finalmente se realizó la actualización de la guía correspondiente al baño húmedo y el diseño de una nueva guía de laboratorio la cual tiene como objetivo desarrollar el proceso de configuración de transmisores de temperatura para lazo de control estandarizado. | en |
dc.description.abstract | This project presents the reorganization of the temperature module of the UPB Bucaramanga instrumentation laboratory, implementing the transmitter configuration process. Initially, the recognition and analysis of the current conditions of the temperature module are presented, as well as the operating conditions. This is carried out through an inventory of each of the instruments that make up the temperature module. Next, the design of the instrument panel structure and the distribution of the elements are carried out, taking into account the space available in the laboratory, the specifications of the instruments and the analysis previously carried out. Later, for the implementation of the temperature transmitters, initially the required configuration was made to put the transmitters into operation. The method used for implementation was a 4-20 mA current loop through a series circuit. To check the operation of the current loop, tests were carried out on the transmitters where the temperature values against resistance and current were recorded. Then, the results obtained from the operational tests were analyzed indicating that the relationship between temperature and current is a completely linear response once the temperature transmitter incorporates the RTD signal and converts it to the standard 4-20 mA. Finally, the update of the guide corresponding to the wet bath and the design of a new laboratory guide was carried out, which aims to develop the process of configuration of temperature transmitters for standardized control loop. | en |
dc.format.mimetype | application/pdf | spa |
dc.language.iso | spa | spa |
dc.rights | Attribution-NonCommercial-NoDerivatives 4.0 Internacional | * |
dc.rights.uri | http://creativecommons.org/licenses/by-nc-nd/4.0/ | * |
dc.subject | Ingeniería Eléctrica | spa |
dc.subject | RTD | spa |
dc.subject | Transmisor | spa |
dc.subject | Lazo de control estandarizado | spa |
dc.subject | respuesta lineal | spa |
dc.title | Reorganización del módulo de temperatura con la implementación del proceso de configuración de transmisores en el laboratorio de instrumentación de la UPB | spa |
dc.type | Proyecto de grado | spa |
dc.publisher.department | Escuela de Ingeniería | spa |
dc.publisher.program | Ingeniería Eléctrica | spa |
dc.type.hasVersion | publishedVersion | spa |
dc.description.sectional | Bucaramanga | spa |
dc.description.degreename | Ingeniería Eléctrica | spa |