dc.coverage.spatialBucaramangaspa
dc.coverage.temporal2021spa
dc.date.accessioned2025-04-29T18:42:44Z
dc.date.available2025-04-29T18:42:44Z
dc.date.issued2021
dc.identifier.urihttp://hdl.handle.net/20.500.11912/12470
dc.description89 Páginasspa
dc.description.abstractDía a día encontramos en nuestro diario vivir, ya sea en el hogar o en nuestros lugares de trabajo la gran necesidad de disminuir las temperaturas en ciertos ambientes cerrados ya que la construcción con concreto y acero aumenta drásticamente la absorción de energía. Por ello se buscó la fabricación de paneles mixtos en base cemento y fibra de coco junto con paneles mixtos en base cemento, fique y adición de aserrín de dimensiones (25x25x4)cm , estos paneles fueron sometidos a una fuente de energía natural y se procedió a analizar su absorción de calor, su transmitancia (norma ASTM C236 – 89) y la temperatura promedio alcanzada por cada panel a diferentes horas del día, haciendo mediciones cada 30mins durante 4horas. Se realizó el análisis estadístico de los resultados mediante el método anova y se compararon los parámetros establecidos en los teoremas de Chebyshev y Box Plot con el fin de comparar ambos modelos de paneles y definir cuál es el que tiene resultados más significativos y por lo tanto sirva mejor como aislante térmico.en
dc.description.abstractEvery day we find in our daily lives, whether at home or in our workplaces, the great need to lower temperatures in certain closed environments since construction with concrete and steel drastically increases energy absorption. For this reason, it was sought to manufacture cement-based mixes and coconut fiber together with cement-based mixed panels, fique and addition of sawdust with dimensions like (25x25x4)cm, These panels were subjected to a natural energy source and their heat absorption and transmittance were analyzed. (norm ASTM C236 – 89) and the average temperature reached by each panel at different times of the day, making measurements every 30 minutes for 4 hours. The statistical analysis of the results was carried out using the anova method and the parameters established in the Chebyshev and Box Plot theorems were compared in order to compare both panel models and define which one has the most significant results and therefore serves better as a thermal insulator.en
dc.format.mimetypeapplication/pdfspa
dc.language.isospaspa
dc.rightsAttribution-NonCommercial-NoDerivatives 4.0 Internacional*
dc.rights.urihttp://creativecommons.org/licenses/by-nc-nd/4.0/*
dc.subjectIngeniería Civilspa
dc.subjectFibra de cocospa
dc.subjectfiquespa
dc.subjectaserrínspa
dc.subjecttransmitanciaspa
dc.subjecttemperaturaspa
dc.subjectaislante térmicospa
dc.titleEvaluación de la transmisibilidad térmica en paneles elaborados con mortero convencional, paneles mixtos de: mortero base cemento, fibra de coco y fique con adición de aserrín.spa
dc.typeProyecto de gradospa
dc.publisher.departmentEscuela de Ingenieríasspa
dc.publisher.programIngeniería Civilspa
dc.type.hasVersionpublishedVersionspa
dc.description.sectionalBucaramangaspa
dc.description.degreenameIngeniero Civilspa


Files in this item

Thumbnail
Thumbnail

This item appears in the following Collection(s)

Show simple item record

Attribution-NonCommercial-NoDerivatives 4.0 Internacional
Except where otherwise noted, this item's license is described as Attribution-NonCommercial-NoDerivatives 4.0 Internacional