Mostrar el registro sencillo del ítem

dc.contributor.advisorCastro Ortiz, Henry
dc.contributor.authorNúnez Herrera, Jorge Armando
dc.contributor.authorSarmiento Garcés, Diana Sofía
dc.coverage.spatialSeccional Bucaramanga. Universidad Pontificia Bolivariana. Escuela de Ingenierías. Facultad de Ingeniería Ambientalspa
dc.coverage.temporal2011
dc.date.accessioned2013-11-05T19:23:05Z
dc.date.available2013-11-05T19:23:05Z
dc.date.created2011-05-27
dc.date.issued2013-11-05
dc.identifier.urihttp://hdl.handle.net/20.500.11912/1217
dc.description105p.: (pdf);il, gráficas; tablas, anexosspa
dc.description.abstractEl área seleccionada para la realización del inventario de emisiones está ubicada en la vía Girón-Bucaramanga desde el puente el Palenque hasta el Colegio la Salle, la cual en los últimos años por estimaciones visuales ha presentando un incremento a nivel industrial, presentándose diversos tipo de industrias entre las que se encuentran metalúrgica, plásticos, textiles, concentrados, bebidas, entre otras. Por esta razón la Autoridad Ambiental Local (CDMB) ha mostrado interés por cuantificar las Emisiones de contaminantes atmosféricos y determinar el impacto sobre el recurso aire que podría afectar a la población en su área de influencia, información con la cual no cuenta actualmente para su seguimiento y control. Para el desarrollo del inventario se siguió la metodología propuesta por el Manual de Fundamentos y Planeación de Inventarios de emisiones, por medio de la cual se identificó que de las 61 industrias presentes, 13 son fuentes fijas de contaminación atmosférica, siendo la emisión más alta la de Material Particulado (PM) con una tasa de emisión de 11,85 Kg/h, debido a procesos de producción como la molienda de trigo de la empresa que genera la mayor emisión de este contaminante y la emisión más baja la de Monóxido de Carbono con un valor de 0,03 Kg/h, caracterizándola así como una zona de baja contaminación al ser comparada con el inventario de emisiones en la zona industrial Chimitá, igualmente se plantearon estrategias de control para reducir las emisiones y se sugirió a la Autoridad Ambiental una metodología de seguimiento y actualización de inventarios en esta zona.spa
dc.description.abstractThe selected area for the emissions inventory execution is located in the GirónBucaramanga route from the bridge El Palenque to school La Salle, which in the past few years by visual estimates have presented an increase at the industrial level presenting various types of industries that are metallurgical, plastics, textiles, concentrated, drinks and some others. Because of this, the local environmental authority (CDMB) has shown interest on the quantification of the atmospheric contaminants emissions and to determinate the impact on the air resource that might affect the population on its influence area, because this information is not currently under monitoring and control. The inventory development followed the methodology proposed on the "Manual de fundamentos y planeación de inventarios de emisiones", through which it was found that out of the 61 present industries, 13 were identified as stationary sources of atmospheric pollution, being the highest emission produced by the particulate material (PM) with an emission rate of 11,85 Kg/h, due to the company production process like wheat grinding, which generates the highest emission of this pollution agent and the lowest carbon monoxide emission of 0,03 Kg/h. Characterizing it as a low pollution area when compared to the emissions inventory on the Chimitá zone, control strategies were proposed to reduce the emissions and zone inventories monitoring and updating methodology was suggested to the environmental authority.
dc.language.isoes
dc.publisherUniversidad Pontificia Bolivarianaspa
dc.rightsAttribution-NonCommercial-NoDerivatives 4.0 International*
dc.rights.urihttp://creativecommons.org/licenses/by-nc-nd/4.0/*
dc.subjectTesis y disertaciones académicasspa
dc.subjectGirón (Santander, Colombia)spa
dc.subjectContaminación del airespa
dc.subjectAutoridades competentes (CDMB)spa
dc.subjectContaminación del aire - medicionesspa
dc.titleInventario de emisiones atmosféricas de las fuentes fijas ubicadas en la vía Girón - Bucaramanga desde el puente el palenque Hasta el colegio la Sallespa
dc.typebacherlorThesisspa
dc.rights.accessRightsopenAccessspa
dc.type.hasVersionpublishedVersionspa
dc.identifier.instnameinstname:Universidad Pontificia Bolivarianaspa
dc.identifier.reponamereponame:Repositorio Institucional de la Universidad Pontificia Bolivarianaspa
dc.identifier.repourlrepourl:https://repository.unab.edu.co/