dc.contributor.advisor | Castillo Pérez, Consuelo | |
dc.contributor.author | Lobo Rojas, Paola Andrea | |
dc.coverage.spatial | Seccional Bucaramanga. Universidad Pontificia Bolivariana. Escuela de Ingenierías. Facultad de Ingeniería Ambiental | spa |
dc.coverage.temporal | 2010 | |
dc.date.accessioned | 2013-08-28T16:59:55Z | |
dc.date.available | 2013-08-28T16:59:55Z | |
dc.date.created | 2010-02-17 | |
dc.date.issued | 2013-08-28 | |
dc.identifier.uri | http://hdl.handle.net/20.500.11912/1043 | |
dc.description | 267p.: (pdf); il; gráficas; tablas; anexos | spa |
dc.description.abstract | Este proyecto fue elaborado con el propósito de evaluar las concentraciones de Material Particulado PM-10, presente en la zona aledaña a la planta de cemento Cemex, mediante el software especializado Breeze ISC Pro. Este se llevo a cabo en tres etapas en las cuales se identificaron las áreas a monitorear, se recopilaron los datos para la modelación y se corrió el modelo para el análisis de los datos obtenidos. El resultado de este proyecto muestra que para el año 2008, según la rosa de los vientos, el comportamiento de la velocidad y la dirección del viento tienden hacia el sur, indicando que el barrio Claverianos está afectado por la contaminación de PM-10, debido a su proximidad a la planta cementera. De acuerdo a las concentraciones modeladas, el índice de calidad de aire para Bucaramanga-IBUCA cataloga la zona según la clasificación epidemiológica como BUENO. Los valores de concentración de las isopletas alto se presentan dentro de la planta Cemex. | spa |
dc.description.abstract | This project was formulated with the aim of assessing concentrations of particulate matter PM-10, present in the vicinity of the Cemex cement plant, using specialized software Breeze ISC Pro This took place in three stages which identified areas to monitor, data were collected for modeling and ran the model for analyzing the data. The result of this project shows that by the year 2008 according to the compass, the behavior of the speed and wind direction tends to the south, indicating that the district Claverianos is affected by the contamination of PM-10, due to its proximity to the cement plant. According to the modeled concentrations, the air quality index for categorizing IBUCA Bucaramanga-zone according to the epidemiological classification as GOOD. The concentration values of high isopleths are presented within the Cemex plant. | |
dc.language.iso | es | |
dc.publisher | Universidad Pontificia Bolivariana | spa |
dc.rights | Attribution-NonCommercial-NoDerivatives 4.0 International | * |
dc.rights.uri | http://creativecommons.org/licenses/by-nc-nd/4.0/ | * |
dc.subject | Tesis y disertaciones académicas | spa |
dc.subject | Ingeniería ambiental | spa |
dc.subject | Material particulado | spa |
dc.subject | Mediciones ambientales | spa |
dc.title | Modelamiento de Dispersión del Material Particulado PM-10 mediante Breeze, en la zona aledaña a la planta productora de cemento CEMEX S.A. ubicada-Bucaramanga | spa |
dc.type | bacherlorThesis | spa |
dc.rights.accessRights | openAccess | spa |
dc.type.hasVersion | publishedVersion | spa |
dc.identifier.instname | instname:Universidad Pontificia Bolivariana | spa |
dc.identifier.reponame | reponame:Repositorio Institucional de la Universidad Pontificia Bolivariana | spa |
dc.identifier.repourl | repourl:https://repository.unab.edu.co/ | |