Determinación de la afectación por olores ofensivos en la comunidad aledaña a la PTAR de Rio Frío

dc.contributor.advisorMagara Gómez, Kento Taro
dc.contributor.authorSerrano Gómez, Nancy Milena
dc.coverage.spatialBucaramanga
dc.coverage.temporal2016
dc.creator.grantorUniversidad Pontificia Bolivariana
dc.date.accessioned2026-05-12T17:01:05Z
dc.date.issued2016
dc.descriptionPáginas 94spa
dc.description.abstractEn conformidad a la queja interpuesta por la comunidad en la CDMB, autoridad ambiental encargada, se dio inicio al protocolo para el monitoreo, control y vigilancia de olores ofensivos sugerido en la normatividad colombiana vigente para casos en los que existan afectaciones por olores en una determinada área poblacional. Se realizó una encuesta en una zona delimitada un 1 Km a la redonda de la posible fuente, en este caso la PTAR de Río Frío, que se presume es la causante de las molestias percibidas por el usuario que interpuso la queja. Este procedimiento arrojo como resultado cualitativo una evidente ratificación de la molestia y afectación generada por la fuente ya mencionada. Para corroborar de formar cuantitativa esta apreciación se aplicó el modelo de dispersión BREEZE AERMOD el cual, con información referente a meteorología, rata de emisión y topografía, entre otros, determina las concentraciones de H2S en un espacio determinado y la dispersión del compuesto en base a las variables ya mencionadas. Las concentraciones calculadas por el modelo generadas desde la fuente mostraron rangos entre 1.753 a 1677.687 µg/m³ en el periodo de 1 hora y de 0.1 a 448.5 µg/m³ en el periodo de 24 horas para el mejor escenario, 8.7628 a 8388.4346 µg/m³ en el periodo de 1 hora y de 0 a 2242µg/m³ en el periodo de 24 horas para el escenario medio y de 17.5257 a 16776.8691 µg/m³en el periodo de 1 hora y de 1 a 4485 µg/m³ en el periodo de 24 horas para el peor escenario. Al comparar ambos procedimientos, se concluye que es importante utilizar herramientas cuantitativas como los modelos matemáticos para establecer resultados reales y confiables que permitan tomar decisiones que solucionen o mitiguen problemáticas que afecten a la comunidad.spa
dc.description.abstractIn conformity to complaints filed by the community to the environmental authority (CMDB), the respective monitoring, control and surveillance of offensive odors health protocol was implemented around the affected area. This protocol complies with current Colombian environmental regulations, in cases which there are offensive odor affectations to people. First, a survey was carried out in a defined area of 1 km radius around the possible main source of offensive odors, the Rio Frio waste water treatment plant. This procedure resulted in an obvious qualitative ratification of discomfort and adverse health effects in population living around the aforementioned possible source of emission of offensive odor. In order to corroborate this, a dispersion model (Breeze AERMOD) was implemented, including meteorological data, calculated emission rates, and topography, among others, using hydrogen sulfide (H2S) as tracer of offensive odor. Concentrations in the studied area ranged between 1,753 and 1677,687 µg/m³ as 1-hour averages, and from 0,1 to 448,5 µg/m³ as 24-hour averages, considering the best scenario, in which H2S content in the flue gas is the minimum found in the literature for similar waste water treatment plants. For an intermediate scenario, concentrations ranged between 8,7628 to 8388,4346 µg/m³ as 1-hour averages, and from 0 to 2242 µg/m³ as 24-h averages; and for worst case scenario, in which H2S concentration is as its maximum value in the flue gas, concentrations ranged between 17,5257 to 16776,8691 µg/m³ as 1-hour averages, and from 1 to 4485 µg/m³ as 24-hour averages. Quantitative results from the model application showed good agreement with survey results, which confirms the importance of assessing odor dispersion through computational tools, as part of the process of proposing solutions to these kind of problems to the community.eng
dc.description.degreenameIngeniero Ambiental
dc.description.sectionalBucaramanga
dc.format.mimetypeapplication/pdf
dc.identifier.urihttp://hdl.handle.net/20.500.11912/13764
dc.language.isospa
dc.publisher.departmentEscuela de Ingeniería
dc.publisher.programIngeniería Sanitaria y Ambiental
dc.rightsAttribution-NonCommercial-NoDerivs 2.5 Colombiaen
dc.rights.urihttp://creativecommons.org/licenses/by-nc-nd/2.5/co/
dc.subjectInstituciones Públicas – CDMB (Corporación Autónoma Regional Para La Defensa De La Meseta De Bucaramanga)spa
dc.subjectOloresspa
dc.subjectControl De Oloresspa
dc.subjectContaminación Del Airespa
dc.subjectSulfuro De Hidrógenospa
dc.titleDeterminación de la afectación por olores ofensivos en la comunidad aledaña a la PTAR de Rio Fríospa
dc.typeTrabajo de Grado
dc.type.hasVersionpublishedVersion

Archivos

Bloque original

Mostrando 1 - 1 de 1
Cargando...
Miniatura
Nombre:
documento (8).pdf
Tamaño:
3.31 MB
Formato:
Adobe Portable Document Format

Bloque de licencias

Mostrando 1 - 1 de 1
Cargando...
Miniatura
Nombre:
Serrano Gómez, Nancy Milena_0001.pdf
Tamaño:
334.97 KB
Formato:
Item-specific license agreed upon to submission
Descripción: