Mostrar el registro sencillo del ítem

dc.contributor.advisorDirector. Durán León, Martha Cecilia
dc.contributor.authorFranco Vargas, Judy Alejandra
dc.coverage.temporal2020
dc.date.accessioned2021-09-27T22:04:53Z
dc.date.available2021-09-27T22:04:53Z
dc.date.issued2021-05
dc.identifier.urihttp://hdl.handle.net/20.500.11912/9315
dc.description51p.: (pdf); il; imágenes; tablas; anexos.spa
dc.description.abstractEl presente informe, tuvo como finalidad documentar los procedimientos necesarios para garantizar que las fuentes de energía peligrosa estén bloqueadas en las diferentes máquinas de la distribuidora Girón de Avidesa Mac Pollo S.A, para cumplir a cabalidad con este objetivo se dio inicio el programa “trabajo seguro con energías peligrosas” y se realizó un recorrido por las instalaciones de la organización en el que se identificaron quince máquinas a incluir en el programa. Para iniciar la documentación, en primera instancia se diligenció el formato “inventario de energías” por cada máquina, en el cual se identificó el tipo de energía presente en cada máquina, el lugar en donde se desenergiza la máquina y el dispositivo de bloqueo idóneo a utilizar, a partir de la documentación del inventario de energías se diligenció el formato de hallazgos en el cual se exponen condiciones a mejorar en las máquinas y su señalización con su respectivo plan de acción para cumplir con el reglamento Técnico Colombiano de instalaciones eléctricas – RETIE, a continuación se documentó la ficha “Cero energías” para cada una de las maquinas en el que se establece el paso a paso para bloquear la energía peligrosa dependiendo del trabajo a realizar en estas.spa
dc.description.abstractThe purpose of the actual report was to document the necessary procedures to guarantee that the hazardous energy sources are blocked in the different machines in Avidesa Mac Pollo S.A. distributor in Giron, in order to comply fully this purpose, the program “safe work with hazardous energy” was initiated, and it was made a tour of the organization facilities where fifteen (15) machines were identified to include in the program. To initiate the documentation, the “energy inventory” format was completed for each machine, which the type of energy was identified for each machine, the place where the machine is de-energized and the proper locking device for use, from the “energy inventory” documentation, the finding format was filled, where the improve conditions in the machines and their signaling with the respective action plan were exposed, with the purpose of comply the Colombian Technical Regulation of Electrical Installations (RETIE), finally, the “Zero energy” tab was documented for each machine which the step by step was established for locking the hazardous energy depending on the work to be done on them.eng
dc.format.mimetypeapplication/pdf
dc.language.isospa
dc.publisherUniversidad Pontificia Bolivarianaspa
dc.rightsAttribution-NonCommercial-NoDerivatives 4.0 International*
dc.rights.urihttp://creativecommons.org/licenses/by-nc-nd/4.0/*
dc.subjectEmpresas - Avidesa Mac Pollo S.Aspa
dc.subjectEnergías peligrosasspa
dc.subjectDiapositivas de bloqueospa
dc.subjectPlan de acciónspa
dc.titleElaboración de la ficha “cero energías” para las maquinas con energía peligrosa de la distribuidora Girón de la empresa Avidesa Mac Pollo S.Aspa
dc.typePrácticaspa
dc.publisher.departmentEscuela de Ingenieríasspa
dc.publisher.programIngeniería Industrialspa
dc.type.hasVersionpublishedVersionspa
dc.description.sectionalBucaramangaspa
dc.description.degreenameIngeniero Industrialspa


Ficheros en el ítem

Thumbnail
Thumbnail

Este ítem aparece en la(s) siguiente(s) colección(ones)

Mostrar el registro sencillo del ítem

Attribution-NonCommercial-NoDerivatives 4.0 International
Excepto si se señala otra cosa, la licencia del ítem se describe como Attribution-NonCommercial-NoDerivatives 4.0 International