Mostrar el registro sencillo del ítem

dc.contributor.advisorMonclou Salcedo, Alex Alberto
dc.contributor.authorSanabria Valdivieso, Miguel Fabián
dc.coverage.spatialSeccional Bucaramanga. Universidad Pontificia Bolivariana. Escuela de Ingenierías. Facultad de Ingeniería Electrónicaspa
dc.coverage.temporal2010
dc.date.accessioned2013-08-28T16:59:33Z
dc.date.available2013-08-28T16:59:33Z
dc.date.created2010-08-03
dc.date.issued2013-08-28
dc.identifier.urihttp://hdl.handle.net/20.500.11912/831
dc.description104p.: (pdf); il; tablas; anexosspa
dc.description.abstractRadiólogos Asociados S.A. es una empresa que brinda sus servicios de radiología e imágenes diagnósticas en la ciudad de Pereira (Risaralda) y Cartago (Valle del cauca). La práctica empresarial es desarrollada en el campo de la bioingeniería y enfocada en los equipos de rayos X. El equipo principal a trabajar es un General Electric, modelo DXR-750II, está ubicado en la sede principal. El objetivo es ayudar a la empresa a reducir el tiempo de respuesta en los mantenimientos correctivos del equipo de rayos X; para este fin, se estudian los planos electrónicos, destacando las tarjetas más importantes e indicando las modificaciones que se le han realizado al equipo a lo largo de su vida. Con la información recopilada, se diseña una tarjeta de detección de errores que permite identificar los problemas de dicho equipo en caso de fallas. Entre los resultados más importantes se destaca la comprensión de todas las etapas del equipo, las condiciones bajo las cuales se produce un haz de rayos X, y el diseño de la tarjeta para la identificación de errores.spa
dc.description.abstractRadiologos Asociados S.A. is an enterprise that offers radiology services and diagnostic imaging at Pereira city (Risaralda) and at Cartago city (Valle del Cauca). The apprenticeship is developed in bioengineering field and focused in X-ray equipment. The machine (brand: General Electric, model DXR-750II) to work with is located at the main headquarter. The main objective is to help the enterprise to diminish the response time when doing corrective maintenance of X- ray equipment. In order to accomplish this, electronic plans must be studied, outstanding the most important electronic boards and showing all the modifications have been made to the equipment. With this information, an error detection board is designed to identify any fail of the equipment. Among all the results, it is important to stand out the understanding of every stage of the equipment, the conditions needed to produce a beam of light; and the design of the error detection board.
dc.language.isoes
dc.publisherUniversidad Pontificia Bolivarianaspa
dc.rightsAttribution-NonCommercial-NoDerivatives 4.0 International*
dc.rights.urihttp://creativecommons.org/licenses/by-nc-nd/4.0/*
dc.subjectIngeniería electrónicaspa
dc.subjectIngeniería biomédicaspa
dc.subjectBioingenieríaspa
dc.subjectMedicina - aparatos e instrumentosspa
dc.titlePráctica empresarial Radiólogos Asociados S.A.spa
dc.typeworkingPaperspa
dc.rights.accessRightsopenAccessspa
dc.type.hasVersionpublishedVersionspa
dc.identifier.instnameinstname:Universidad Pontificia Bolivarianaspa
dc.identifier.reponamereponame:Repositorio Institucional de la Universidad Pontificia Bolivarianaspa
dc.identifier.repourlrepourl:https://repository.unab.edu.co/


Ficheros en el ítem

Thumbnail

Este ítem aparece en la(s) siguiente(s) colección(ones)

Mostrar el registro sencillo del ítem

Attribution-NonCommercial-NoDerivatives 4.0 International
Excepto si se señala otra cosa, la licencia del ítem se describe como Attribution-NonCommercial-NoDerivatives 4.0 International