Mostrar el registro sencillo del ítem
Comparación de dos técnicas de medición de flujo correspondientes a un probador bidireccional y un sensor tipo coriolis
dc.contributor.advisor | Director. Hernández Arroyo, Emil | |
dc.contributor.author | Bernal Navarro, Miguel Felipe | |
dc.coverage.temporal | 2018 | |
dc.date.accessioned | 2020-04-24T14:47:05Z | |
dc.date.available | 2020-04-24T14:47:05Z | |
dc.date.issued | 2018 | |
dc.identifier.uri | http://hdl.handle.net/20.500.11912/5242 | |
dc.description | 54p.: (pdf); il; imágenes; gráficas; tablas; anexos. | spa |
dc.description.abstract | Existen diferentes tipos de probadores para medidores de flujo como son los probadores unidireccionales de pistón o esfera. probadores para volúmenes pequeños, probadores bidireccionales de esfera. Sobre este último se realiza un estudio en el cual se comparan dos técnicas diferentes de medición de flujo usando un probador bidireccional y un sensor de flujo tipo Coriolis simultáneamente. El probador bidireccional se construyó por estudiantes de ingeniería mecánica de la Universidad Pontifica Bolivariana el sensor de flujo tipo Coriolis se elige de acuerdo a la presión caudal y demás especificaciones del sistema, a su vez se realiza la instalación y acondicionamiento de este. Al comparar las dos técnicas de medición de flujo se concluyó que los valores de caudal obtenidos simultáneamente por cada sensor no varían significativamente la prueba de hipótesis tiene un valor probabillstico (Valor-p) de 9.4%. | spa |
dc.description.abstract | There are different types of testers for flow meters such as unidirectional piston or dial testers, testers for small, bidirectional sphere testers. On the latter, a study was carried out in which two different flow measurement techniques were compared using a bidirectional tester and a Coriolis type flow sensor simultaneously. The bidirectional tester was built by mechanical engineering students of the Universidad Pontificia Bolivariana. The Coriolis type flow sensor chooses the agreement to the flow pressure and the other requirements of the system, in turn, the installation and conditioning of it. The hypothesis comparison has a probabilistic value (value-p) of 9.4%. | eng |
dc.format.mimetype | application/pdf | |
dc.language.iso | spa | |
dc.publisher | Universidad Pontificia Bolivariana | spa |
dc.rights | Attribution-NonCommercial-NoDerivatives 4.0 International | * |
dc.rights.uri | http://creativecommons.org/licenses/by-nc-nd/4.0/ | * |
dc.subject | Universidades - UPB (Universidad Pontificia Bolivariana) | spa |
dc.subject | Detectores | spa |
dc.subject | Medición | spa |
dc.subject | Contadores de fluidos | spa |
dc.title | Comparación de dos técnicas de medición de flujo correspondientes a un probador bidireccional y un sensor tipo coriolis | spa |
dc.type | Práctica | spa |
dc.publisher.department | Escuela de Ingenierías | spa |
dc.publisher.program | Ingeniería Mecánica | spa |
dc.type.hasVersion | publishedVersion | spa |
dc.description.sectional | Bucaramanga | spa |
dc.description.degreename | Ingeniero Mecánico | spa |
Ficheros en el ítem
Este ítem aparece en la(s) siguiente(s) colección(ones)
-
Trabajos de grado [6348]
Monografías, artículos, informes, proyecto de grado