Abstract
El tratamiento con Eichhornia Crassipes es una alternativa eficaz para el postratamiento del efluente del reactor anaerobio a flujo pistón, poseen un sistema de raíces que pueden tener microorganismos asociados a ellas ayudando la acción depuradora de las plantas acuáticas. A fin de evaluar la eficiencia de un sistema de recuperación de aguas residuales, para el postratam ento del efluente del Reactor, se realizó la caracterización del efluente del sistema realizando pruebas fisicoquímicas y microbiológicas, adicionalmente se evaluó el crecimiento de la Eichhornia Crassipes en el sistema bajo condiciones normales de operación, y se diseñó una alternativa de tratamiento para los subproductos generados en el proceso. Los resultados confirmaron que los parámetros que reportaron mayores eficiencias de remoción fueron la Demanda Biológica de Oxigeno con un 86.78% y los sólidos suspendidos totales con un 83.69%, permitiendo comprobar su eficiencia y dar cumplimiento al decreto 1594 de 1984, ... Treatment with Eichhornia crassipes is an effective alternative for the effluent
aftercare from anaerobic piston reactors. These plants have a root system that
may have associated microorganisms that improve aquatic plants purifying
capabilities.
To evaluate the efficiency of a waste-water recovering system for the reactor
effluent aftercare, a characterization of the effluent was carried out by
physicochemical and microbiological tests. In adition, Eichhornia crassipes
growth was tested, all this under normal operation conditions. Additionally, an
alternative treatment for the sub products generated in the process was
designed.
The results confirmed that the parameters that reported greater removal
efficiencies were biological oxygen demand (86.78%) and total suspended
solids (83.69%). This allowed the verification of their efficiency and ensured
compliance to 1594 decree, 1984. It was found that the plants can double its
weight every 15 days, which affirms its reproductive ...