dc.description44p.: (pdf); il; tablas; anexosspa
dc.description.abstractLa estabilidad operacional de la unidad regeneradora de glicol (quemador FH-54101) Juega un papel importante dentro del proceso de producción de petróleo crudo, ya que el no lograr deshidratar las cantidades de gas producidas originan cierres temporales en los pozos de producción o operar recirculando, es decir a baja carga. La monografía aquí desarrolla centra su atención en el sistema de control del quemador (Control en Cascada) y desarrolla un procedimiento que reúne la información básica operativa del mismo y información técnica del funcionamiento de este sistema de control. Retardos en los arranques generando perdidas de producción que son las principales razones entre otras, para desarrollar un procedimiento que documente la experiencia técnica reunida del grupo de instrumentación, Las fallas y sus posibles soluciones que pueden ocasionar dificultades generando paradas no programas de este equipo y fallas que se presentan durante la puesta en línea de la unidad, son documentadas en el procedimiento. Se pretende con este documento mejorar el tiempo de respuesta para la puesta en línea de esta unidad evitando perdidas de producción y elevar el nivel de competencia del grupo de instrumentación.spa
dc.description.abstractThe operational stability of the glycol regeneration unit (burner FH-54 101) plays an important role in the process of crude oil, since failing to dehydrate the gas quantities produced originate closures in the production wells or operate recirculating ie at low loads. The monograph develops here focuses on the burner control system (Cascade Control) and develops a procedure that meets the basic information of the same operational and technical information of how this control system. Delays in the production starts generating losses are the main reasons among others, to develop a procedure that documents the technical expertise of the group gathered instrumentation failures and possible solutions that may cause difficulties creating downtime for this equipment and software failures occur during the start-line unit, are documented in the procedure. This document is intended to improve response time for the start line of this unit to avoid production losses and raise the competence level of the instrumentation group.
dc.language.isoes
dc.publisherUniversidad Pontificia Bolivarianaspa
dc.rightsAttribution-NonCommercial-NoDerivatives 4.0 International*
dc.rights.urihttp://creativecommons.org/licenses/by-nc-nd/4.0/*
dc.subjectEspecialización en instrumentación y controlspa
dc.subjectGlycol - Cusianaspa
dc.subjectQuemadores de petróleo - FH 54101spa
dc.subjectPetróleospa
dc.subjectPetróleo - Prospecciónspa
dc.titleProcedimiento para análisis y solución de fallas de encendido y control del reboiler de la unidad regeneradora de glycol cusiana fase IIspa
dc.typebookspa
dc.rights.accessRightsopenAccessspa
dc.type.hasVersionpublishedVersionspa
dc.identifier.instnameinstname:Universidad Pontificia Bolivarianaspa
dc.identifier.reponamereponame:Repositorio Institucional de la Universidad Pontificia Bolivarianaspa
dc.identifier.repourlrepourl:https://repository.unab.edu.co/


Ficheros en el ítem

Thumbnail
Thumbnail

Este ítem aparece en la(s) siguiente(s) colección(ones)

Mostrar el registro sencillo del ítem

Attribution-NonCommercial-NoDerivatives 4.0 International
Excepto si se señala otra cosa, la licencia del ítem se describe como Attribution-NonCommercial-NoDerivatives 4.0 International